Biomechanical aspects of locking reconstruction plate positioning in osteosynthesis of transverse clavicle fracture / Egidijus Kontautas, Andrej Pijadin, Andrius Vilkauskas, Aurelijus Domeika
Type of publication
Straipsnis Web of Science ir Scopus duomenų bazėje / Article in Web of Science and Scopus database (S1)
Author(s)
Vilkauskas, Andrius | Kauno technologijos universitetas |
Domeika, Aurelijus | Kauno technologijos universitetas |
Title
Biomechanical aspects of locking reconstruction plate positioning in osteosynthesis of transverse clavicle fracture / Egidijus Kontautas, Andrej Pijadin, Andrius Vilkauskas, Aurelijus Domeika
Publisher (trusted)
Lietuvos sveikatos mokslų universitetas |
Is Referenced by
Date Issued
Date Issued |
---|
2012-02-01 |
Extent
p. 80-83.
Is part of
Medicina. Kaunas : Lietuvos sveikatos mokslų universitetas, 2012, t. 48, Nr. 2.
Version
Originalus / Original
Series/Report no.
Clinical investigations
Field of Science
Abstract
The aim of this study was to evaluate and compare the biomechanical effects of locking reconstruction plate positioning on the osteosynthesis of clavicle midshaft simulated transverse fractures. Material and Methods. Twelve synthetic clavicles with simulated midshaft transverse fractures were repaired with a 3.5-mm locking reconstruction plate in the anteroinferior or the superior position. The clavicles were randomly assigned to 2 groups (6 per group). Each repaired clavicle was tested in cantilever bending by using the universal testing machine. The maximal load and the displacement of the specimens at a load of 40 N were recorded for each group. Results. The anteroinferior plating osteosynthesis with a 3.5-mm locking reconstruction plate could bear an average maximal load of 183.3 N (SD, 11.3); the corresponding load for the superior plating osteosynthesis with the identical implants was 444.8 N (SD, 102.3), and the mean displacement was 1.5 mm (SD, 0.5) and 0.7 mm (SD, 0.2), respectively. Conclusions. The superior plating osteosynthesis of simulated midshaft transverse clavicle fractures with the 7-hole 3.5-mm locking reconstruction plate had a significantly higher bending (from top to bottom) load to failure in comparison with the anteroinferior plating osteosynthesis of the clavicle with the identical implants. Clavicles plated with the 7-hole 3.5-mm locking reconstruction plate at the superior aspect exhibited a significantly greater biomechanical stability at a load of 40 N than those plated at the anteroinferior aspect.
Type of document
type::text::journal::journal article::research article
ISSN (of the container)
1010-660X
WOS
000304283800003
Other Identifier(s)
(LSMU ALMA)990000785840107106
Coverage Spatial
Lietuva / Lithuania (LT)
Language
Anglų / English (en)
Bibliographic Details
23
Journal | IF | AIF | AIF (min) | AIF (max) | Cat | AV | Year | Quartile |
---|---|---|---|---|---|---|---|---|
Medicina-Lithuania | 0.55 | 3.934 | 3.934 | 3.934 | 1 | 0.14 | 2012 | Q3 |
Journal | IF | AIF | AIF (min) | AIF (max) | Cat | AV | Year | Quartile |
---|---|---|---|---|---|---|---|---|
Medicina-Lithuania | 0.55 | 3.934 | 3.934 | 3.934 | 1 | 0.14 | 2012 | Q3 |
Journal | Cite Score | SNIP | SJR | Year | Quartile |
---|---|---|---|---|---|
Medicina | 1 | 0.398 | 0.22 | 2012 | Q3 |