Use this url to cite publication: https://hdl.handle.net/20.500.12512/34282
Options
Irradiating single cells using Cracow microprobe facility / Polak W., Veselov O., Lekki J., Stachura Z., Zazula M., Ugenskiene R., Polak M., Styczen J
Type of publication
Straipsnis Web of Science duomenų bazėje / Article in Web of Science database (S1a)
Author(s)
Polak, W. | Institute of Nuclear Physics PAN, Cracow, Poland |
Veselov, O. | Institute of Nuclear Physics PAN, Cracow, Poland |
Lekki, J. | Institute of Nuclear Physics PAN, Cracow, Poland |
Stachura, Z. | Institute of Nuclear Physics PAN, Cracow, Poland |
Zazula, M. | Department of Pathomorphology, Collegium Medicum, Jagiellonian University, Krakow, Poland |
Jagiellonian University, Medical College, Cracow, Poland | |
Polak, M. | Institute of Nuclear Physics PAN, Cracow, Poland |
Styczen, J. | Institute of Nuclear Physics PAN, Cracow, Poland |
Title
Irradiating single cells using Cracow microprobe facility / Polak W., Veselov O., Lekki J., Stachura Z., Zazula M., Ugenskiene R., Polak M., Styczen J
Publisher (trusted)
Elsevier Science BV
Date Issued
2006-04-01
Extent
p. 743-746.
Is part of
Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms : 17th International Conference on Ion Beam Analysis Seville, Spain, Juny 26-July 01, 2005 University Autonoma Madrid; University Sevilla; Junta Andalucia; Ministry Education & Ciencia; Consejo Superior Investigaciones Cient; Intitute Atomic Energy Agcy; European Act COST G8; Boem Phys Soc; High Voltage Engn Europa BV; Banco Santander Cent Hispano; Schering Espana. , 2006, vol. 249.
Version
Originalus / Original
Field of Science
Keywords
Abstract
The Cracow single ion hit facility (SIH) is using the Van de Graaff-based microprobe with current spatial resolution of about 10 mu m in vacuum. Living cells are irradiated with the exact number of 2 MeV protons. This work shows the present setup and test measurements optimizing the detection of single protons, beam deflection after registering single proton and the accuracy of cell targeting as well as the description of performance of the whole setup. The article presents also ways of cells visualisation and positioning during a single measurement and reports on first experiments with living cells carried out at the new facility. (c) 2006 Elsevier B.V. All rights reserved.
Is Referenced by
Type of document
type::text::journal::journal article
ISSN (of the container)
0168-583X
WOS
000239545000180
Other Identifier(s)
(LSMU ALMA)990000117620107106
Coverage Spatial
Ispanija / Spain (ES)
Language
Anglų / English (en)
Bibliographic Details
10
Journal | IF | AIF | AIF (min) | AIF (max) | Cat | AV | Year | Quartile |
---|---|---|---|---|---|---|---|---|
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS | 0.946 | 1.517 | 0.888 | 2.378 | 4 | 0.738 | 2006 | Q1 |
Journal | IF | AIF | AIF (min) | AIF (max) | Cat | AV | Year | Quartile |
---|---|---|---|---|---|---|---|---|
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS | 0.946 | 1.517 | 0.888 | 2.378 | 4 | 0.738 | 2006 | Q1 |